PCC COLOUR CODED PRESSURE GAUGE

DESCRIPTION & FEATURES

  • Unique pressure instrument with color-coded cases for easy process identification.
  • 4 UV-resistant colors that won’t fade over time.
  • Available with stainless steel or brass internals, and liquid-fillable for durability.
  • ASME B40.100 compliant and CRN registered for industry standards.
  • 5-year warranty for long-term reliability.

Applications

  • Ideal for quick identification of process or pressure.
  • Designed for machinery, process lines, compressors, and hydraulic systems.
  • Performs well in high-vibration and pulsating environments.

SPECIFICATIONS

 Stainless Steel InternalsBrass Internals
Dial4” (100mm) white aluminum with black and red markings4” (100mm) white aluminum with black and red markings
CasePBT Polybutylene terephthalate – colour codedPBT Polybutylene terephthalate – colour coded
LensPolycarbonatePolycarbonate
RingPBT Polybutylene terephthalate – colour codedPBT Polybutylene terephthalate – colour coded
Socket316L SSOT 58 brass
Connection1/4” NPT or 1/2” NPT standard1/4” NPT or 1/2” NPT standard
Bourdon Tube316L SS, drawn seamlessPhosphor bronze
Movement304 SSGears are OT 59 brass, plates are AISI 304 SS
PointerAluminum, anodized black, micrometer adjustableAluminum, anodized black
WeldingTIG, silver alloy

Tin/copper alloy for pressures up to 600 psi (4,137 kPa),

Silver alloy for pressures over 600 psi (4.137 kPa)

Over-Pressure Limit

30% for pressures up to 600 psi (4,137 kPa),

15% for pressures over 600 psi (4,137 kPa)

25% for pressures up to 1,400 psi (9,653 kPa),

15% for pressures over 1,400 psi (9,653 kPa)

Gasket Material   EPDM

Silicone rubber for socket

EPDM for lens, filling plug and blow-out vent

Working PressureMaximum 75% of full scale valueMaximum 75% of full scale value
Ambient/Process Temperature

Dry: -40°F to 200°F (-40°C to 93°C)

Glycerin Filled: -40°F to 150°F (-40°C to 65°C)

Dry: -40°F to 200°F (-40°C to 93°C)

Glycerin Filled: -40°F to 150°F (-40°C to 65°C)

Accuracy±1% ANSI/ASME Grade 1A±1% ANSI/ASME Grade 1A
Enclosure RatingIP65 per EN60529-1 (IEC529-1)IP65 per EN60529-1 (IEC529-1)
Warning (brass internals only)N/A Warning: This product can expose you to chemicals including lead, which is known to the State of California to cause cancer and birth defects or other reproductive harm.  For more information go to www.P65Warnings.ca.gov.

 