| Input |
4/20 mA + HART, 2-wire / V = 9-32 VDC |
| LCD Display |
Available with LCD display (standard) or without LCD display (optional) |
| Accuracy |
0.1% URL standard |
| Stability |
0.2% of URL for two years |
| Temperature Ranges |
Working/Media temperature: -25/95°C (with display -13/203°F), -40/185°C (without display -4/158°F)
Ambient temperature: -40/60°C (with display -40/140°F), -40/115°C (without display -4/240°F)
Storage temperature: -40/110°C (with display -40/85°F), -40/230°C (without display -40/446°F)
|
| Working Humidity |
0-100% relative humidity |
| Pressure Connection |
1/2” NPT M or F, G1/2”, M20*1.5 |
| Housing |
304SS, 316SS, Rugged die-cast aluminum housing (painted Blue) |
| Wetted Parts |
316 SS process connection, 316 L diaphragm |
| Response Time |
200ms |
| Turn On Time |
2 seconds (with minimum damping enabled) |
| Power Consumption |
<162.8 mW |
| Vibration Effect |
+/- 0.005% of URL per G to 200 Hz, in accordance to IEC60770-1:1999 |
| Available Pressure Units |
kPa, Mpa, bar, psi, mmHg, mmH2O, mH2O, inH2O, ftH2O, inHg, mHg, TORR, mbar, g/cm2, kg/cm2, Pa, ATM, m, cm, mm |
| Protection Class |
EMC, reverse polarity protected |
| Approval |
ATEX, II 2 G Ex db IIC T6 Gb
ATEX, II 1 G Ex ia IIC T1~T6 Ga
Intrinsically safe parameters: Ui=28Vdc, Ii=93mA, Pi=0.65W, Ci=5nF, Li=0 mH
|
| Protection Class |
IP66 |
| Weight |
5.95 lbs (2.7 kg) |
| Operational Life |
100 million cycles |